✓ TradeExamPro

TradeExamPro › Plumbing & Gas

Gas Fitter Practice Test: Natural Gas & Propane

Gas properties, combustion, piping and sizing concepts, regulators, appliances, venting, leak testing and safety for gas fitter and LP gas exams.

191 questions · 7 topics · free, no sign-up

Mixed practice test

10 questions, graded as you go, with the reason for every answer. No sign-up.

Timed mock exam

50 questions in 60 minutes, drawn from every topic. No answers shown until the end, then a score, your weakest topics and a review of what you missed.

Practise by topic

Sample questions

What does the pressure switch on an induced-draft furnace prove before ignition is allowed?

  1. That the gas supply pressure at the valve inlet is high enough
  2. That the circulating blower is moving air across the heat exchanger
  3. That the air filter is clean enough for the furnace to run safely
  4. That the inducer is moving air through the heat exchanger and vent
Show the answer

D. That the inducer is moving air through the heat exchanger and vent

The switch senses the negative pressure created by the draft inducer, confirming that combustion air is flowing and the vent is not blocked. It does not measure gas pressure, despite its name.

Reference: Appliance manufacturer installation and service instructions

About how many cubic feet of air are needed to completely burn one cubic foot of natural gas?

  1. 2 cubic feet
  2. 5 cubic feet
  3. 10 cubic feet
  4. 24 cubic feet
Show the answer

C. 10 cubic feet

Natural gas needs about 10 cubic feet of air per cubic foot of gas for complete combustion. About 24 cubic feet is the figure for propane, which has more carbon and hydrogen in each cubic foot.

Reference: Combustion fundamentals; NFPA 54 Annex

What does the fixed maximum liquid level gauge (bleeder valve) tell the person filling a propane tank?

  1. The pressure inside the tank in psi
  2. The temperature of the liquid in the tank
  3. That the tank has no air or water in it
  4. That the liquid has reached the maximum fill level
Show the answer

D. That the liquid has reached the maximum fill level

A dip tube ends at the maximum permitted liquid level. During filling the bleeder is opened; when it changes from clear vapor to a white liquid mist, the tank is full and filling stops.

Reference: NFPA 58 Sections 5.9 and 7.4 (fixed maximum liquid level gauge)

Which of these materials is not permitted for fuel gas piping under the IFGC?

  1. Schedule 40 steel pipe
  2. Cast-iron pipe
  3. Corrugated stainless steel tubing
  4. Polyethylene pipe underground
Show the answer

B. Cast-iron pipe

Cast-iron pipe is specifically excluded from gas piping. Steel pipe, listed CSST and polyethylene (outdoors, underground) are all recognized materials.

Reference: IFGC 2021 Section 403; NFPA 54 Section 5.6.2

What is one British thermal unit (Btu)?

  1. The heat needed to raise 1 lb of water by 1 degree F
  2. The heat needed to raise 1 gal of water by 1 degree F
  3. The heat needed to boil away 1 lb of water at 212 F
  4. The heat given off by 1 cubic foot of any fuel gas
Show the answer

A. The heat needed to raise 1 lb of water by 1 degree F

One British thermal unit raises one pound of water one degree Fahrenheit. A gallon of water weighs about 8.33 lb, so heating a gallon one degree takes about 8.33 Btu, not 1.

Reference: Basic heat units; ASHRAE Fundamentals

Exams this helps with

ExamWho runs itWhere
Gas fitter / gas piping readyState and local boardsUnited States (varies by state)
LP gas / propane technician (CETP) readyPERC, state boardsUnited States (varies by state)

Tell us what to improve · More plumbing & gas practice